A fixed pulley redirects a counterbalance cable, but the two cable legs both load its support. The bracket reaction depends on their directions as well as their tensions. It is not generally equal to the spring pull entered on a quotation.

Draw the two cable legs
Show the cable directions at the pulley in the actual installation. Treat each leg as a force acting on the pulley, then combine those forces using their directions. In an ideal arrangement the tensions may be equal; bearing and routing losses can make the real values different.
Where both legs pull largely in the same direction, the support reaction can be much larger than one cable tension. Where the cable changes direction less, the reaction has a different magnitude and direction. Keep the geometry attached to any bracket load calculation.
Follow the reaction into the structure

Identify the axle, bracket, fasteners and supporting frame. A bracket offset can add a moment at its mounting surface. A spring that fits the carriage requirement does not establish that this load path is acceptable.
Review changes in cable angle through travel. A remote attachment or moving guide may rotate the resultant load even when nominal spring output remains nearly constant. Use the positions that matter to the support design, not just the easiest position to photograph.
For a joint review, provide the two cable directions, their measurement locations and the bracket mounting datum. Keep spring qualification and support qualification as separate decisions. This is particularly helpful when one supplier provides the spring and another supplies the pulley assembly: the force transmitted between them needs an agreed definition.

For the broader background, read Constant Force Spring Attachment Alignment and Side Load.
Explore related spring information or discuss this mechanism with a non-confidential description.
Background reference: THK applied loads and moments. Component documentation does not qualify the complete mechanism.