Homing travel and useful counterbalance travel are different intervals. A vertical axis may run toward its machine reference before normal operation begins. If that movement carries the spring into its take-up region, the assistance during homing can differ from the assistance assumed for the working stroke.

Put both references on one drawing
Mark the machine home reference, the spring's installed position and the normal operating limits using a common axis. Include the sensing target and any approach distance required by the controller. A home switch location alone does not describe the full movement used to establish the reference.
Ask which physical position corresponds to the force measurements on the spring drawing. If the controller later applies a coordinate offset, that software offset does not move the spring or expand its usable travel.
Review the approach and return

Check the assistance during the homing approach, the change of direction and the move into the working interval. The drive may see a different load before the spring reaches its required output region. Use the actual machine sequence rather than testing only the final referenced position.
Keep independent travel protection within the mechanical design. A successful homing routine is not permission to use full spring payout as an end stop, and changing a switch position should not silently change the spring's permitted extension.
For a revision, retain the previous reference location and identify what moved: sensor, target, spring support or controller offset. Then recheck the physical interval. This avoids a common documentation trap in which the displayed coordinate still reads zero while the spring starts from a different installed condition.

For the broader background, read Constant Force Spring Startup Travel: What to Leave Outside the Working Stroke.
Explore related spring information or discuss this mechanism with a non-confidential description.