An optical sensor can be affected by a moving spring, cable or attachment that crosses its path before the intended target. The local clearance review needs to follow every relevant moving feature, not just the component named in the sensor drawing.

Draw the optical path into the mechanism
Identify the selected sensor's intended operating arrangement and target. Show the spring and cable positions at the same stages. Use the sensor supplier's installation requirements; the visible housing outline is not a definition of its optical function.
A small bracket or boot revision can matter if it moves an edge into the relevant path. Include those parts in the configuration record.
Check signal and motion together

Observe the intended target and sensor signal under the approved evaluation. A signal that changes early may be responding to another moving object. Moving the sensor until the sequence appears correct is not a substitute for identifying that object.
Review the parked and intermediate positions as well as the nominal sensing point. Slack cable or an attachment that rotates can create a different obstruction on the return path.
The spring's task is to provide the defined movement contribution. Detection belongs to a separately specified sensing interface. Keep both references in the handover so that later mechanical changes do not silently invalidate a previously accepted optical arrangement.

For the broader background, read Spring Torque Ripple from an Eccentric Drum.
Explore related spring information or discuss this mechanism with a non-confidential description.